AMX - Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
- Level of performance without an external controller: PL = d
- Level of performance with AWAX controller: up to PL = e
- Safety category without an external controller: 3
- Safety Integrity Level: SIL 2
- Cycle after dangerous failure: B10d = 2,000,000 at 2A
- Max. activation distance: 10 mm, 2 mm hysteresis
- Security contacts / diagnostics AMX5 / AMX5CM12 : 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary
- Security contacts AMX4: 2 x NO 2A/48V redundant
- Security contacts / diagnostics AMX3 : 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary
- Detection encoding: mono-code inviolable
- Indicator: LED indicates code recognition
- Reset: automatic
- Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
- Mounting position: 2 (double wall brackets)
- Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ?or PC (AMX5CM12)
- Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12)
- Water resistance: IP 68 (PA6) or IP 69K with stainless steel - new generation
- Temperature: -25°C to +60°C
- Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability
- Certification: TÜV Rheinland 01/205/5238/12
- License Test Mark 968/EL 214.01/12
- UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)
Differences between the products in the AMX range :
AMX3 :
AMX4 :
AMX5 :